{"product_id":"amensolar-hybrid-inverter-12000w-n3h-x12us-200a","title":"AMENSOLAR HYBRID INVERTER -12000W - N3H-X12US (200A)","description":"\u003ch3 class=\"MsoNormal\"\u003e\u003cstrong\u003e\u003cspan lang=\"EN-US\"\u003eFreight shipping will be calculated per order, please call or email for freight shipping quote.  \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1174\" data-end=\"1213\"\u003e \u003c\/p\u003e\n\u003ch2\u003eAmensolar N3H-X12US 12kW Split Phase Hybrid Inverter\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAmensolar N3H-X12US\u003c\/strong\u003e is a 12kW split phase hybrid inverter designed for solar, battery storage, grid-tied, backup power, and generator-supported energy systems. Built for North American electrical configurations, this inverter supports \u003cstrong\u003e110\/220V, 120\/240V split phase, 208V, and 230V systems\u003c\/strong\u003e, making it suitable for residential and light commercial solar energy installations.\u003c\/p\u003e\n\u003cp\u003eWith \u003cstrong\u003e18kW maximum PV input\u003c\/strong\u003e, \u003cstrong\u003e4 independent MPPT trackers\u003c\/strong\u003e, \u003cstrong\u003e48V battery compatibility\u003c\/strong\u003e, and \u003cstrong\u003e200A maximum grid passthrough current\u003c\/strong\u003e, the N3H-X12US is built for flexible solar plus storage setups. It also supports multiple operating modes, including self-use, battery priority, peak shifting, generator function, AC coupling, and parallel connection for increased system power.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSolar PV Input\u003c\/h2\u003e\n\u003cp\u003eThe Amensolar N3H-X12US supports up to \u003cstrong\u003e18kW of maximum DC input power\u003c\/strong\u003e, helping installers design solar systems with strong PV capacity. Its \u003cstrong\u003e4 MPPT trackers\u003c\/strong\u003e allow multiple solar input strings to operate independently, improving flexibility for different roof sections, panel orientations, or system layouts.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum DC input power: 18kW\u003c\/li\u003e\n\u003cli\u003eNumber of MPPT trackers: 4\u003c\/li\u003e\n\u003cli\u003eMPPT voltage range: 120V to 430V\u003c\/li\u003e\n\u003cli\u003eMaximum DC input voltage: 500V\u003c\/li\u003e\n\u003cli\u003eMaximum input current per MPPT: 16A \/ 16A \/ 16A \/ 16A\u003c\/li\u003e\n\u003cli\u003eMaximum short circuit current per MPPT: 22A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBattery Storage Compatibility\u003c\/h2\u003e\n\u003cp\u003eThis 12kW hybrid inverter is designed for \u003cstrong\u003e48V battery systems\u003c\/strong\u003e and supports both \u003cstrong\u003elithium\u003c\/strong\u003e and \u003cstrong\u003elead-acid\u003c\/strong\u003e battery types. The battery voltage range is 40V to 58V, with high charge and discharge current capacity for solar battery backup applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal battery voltage: 48V\u003c\/li\u003e\n\u003cli\u003eBattery voltage range: 40V to 58V\u003c\/li\u003e\n\u003cli\u003eBattery type: Lithium \/ Lead-acid\u003c\/li\u003e\n\u003cli\u003eMaximum charging current: 250A\u003c\/li\u003e\n\u003cli\u003eMaximum discharging current: 260A\u003c\/li\u003e\n\u003cli\u003eCharging controller: 3-stage with equalization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOn-Grid AC Output\u003c\/h2\u003e\n\u003cp\u003eThe N3H-X12US provides \u003cstrong\u003e12kVA nominal AC output to the grid\u003c\/strong\u003e with a maximum apparent power output of \u003cstrong\u003e13.2kVA\u003c\/strong\u003e. It supports 50\/60Hz operation and includes a maximum grid passthrough current of \u003cstrong\u003e200A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power to grid: 12kVA\u003c\/li\u003e\n\u003cli\u003eMaximum apparent power output to grid: 13.2kVA\u003c\/li\u003e\n\u003cli\u003eNominal AC voltage: 110V to 120V \/ 220V to 240V split phase, 208V 2\/3 phase, 230V 1 phase\u003c\/li\u003e\n\u003cli\u003eNominal AC frequency: 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eNominal AC current: 50A\u003c\/li\u003e\n\u003cli\u003eMaximum AC current: 55A\u003c\/li\u003e\n\u003cli\u003eMaximum grid passthrough current: 200A\u003c\/li\u003e\n\u003cli\u003eOutput THDi: \u0026lt;3%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBackup Power Output\u003c\/h2\u003e\n\u003cp\u003eFor backup power applications, this inverter provides \u003cstrong\u003e12kVA nominal apparent power\u003c\/strong\u003e and supports \u003cstrong\u003e120\/240V backup output\u003c\/strong\u003e at 60Hz. With PV input available, the maximum apparent backup power listed by the supplier is \u003cstrong\u003e13.2kVA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal apparent power: 12kVA\u003c\/li\u003e\n\u003cli\u003eMaximum apparent power without PV: 12kVA\u003c\/li\u003e\n\u003cli\u003eMaximum apparent power with PV: 13.2kVA\u003c\/li\u003e\n\u003cli\u003eNominal backup output voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eNominal backup output frequency: 60Hz\u003c\/li\u003e\n\u003cli\u003eOutput power factor: 0.8 leading to 0.8 lagging\u003c\/li\u003e\n\u003cli\u003eOutput THDu: \u0026lt;2%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEfficiency\u003c\/h2\u003e\n\u003cp\u003eThe Amensolar N3H-X12US is designed for efficient solar conversion, battery charging, and battery-to-load operation. It reaches a listed \u003cstrong\u003e99.9% MPPT efficiency\u003c\/strong\u003e and up to \u003cstrong\u003e96.5% maximum PV-to-grid efficiency\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMPPT efficiency: 99.9%\u003c\/li\u003e\n\u003cli\u003eEurope efficiency, PV: 96.2%\u003c\/li\u003e\n\u003cli\u003eMaximum PV-to-grid efficiency: 96.5%\u003c\/li\u003e\n\u003cli\u003eMaximum PV-to-battery charging efficiency: 95.8%\u003c\/li\u003e\n\u003cli\u003eMaximum battery-to-load efficiency: 94.6%\u003c\/li\u003e\n\u003cli\u003eMaximum grid-to-battery charging efficiency: 94.5%\u003c\/li\u003e\n\u003cli\u003eSelf-consumption: \u0026lt;25W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSmart Monitoring and Communication\u003c\/h2\u003e\n\u003cp\u003eThe N3H-X inverter series supports intelligent monitoring through the \u003cstrong\u003eSolarman App\u003c\/strong\u003e, allowing users to view system data remotely. Monitoring data can include power generation, battery power, grid sales data, load power consumption, equipment information, and power station alarms.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication with BMS \/ Meter \/ EMS: RS485, CAN\u003c\/li\u003e\n\u003cli\u003eSupported communication interface: RS485, 4G optional, Wi-Fi\u003c\/li\u003e\n\u003cli\u003eRemote monitoring: Solarman App\u003c\/li\u003e\n\u003cli\u003eDisplay: LCD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProtection and Safety Features\u003c\/h2\u003e\n\u003cp\u003eThe Amensolar N3H-X12US includes multiple built-in protection functions for solar, battery, backup, and grid-connected operation. These features help support safer system performance when installed according to applicable electrical codes and manufacturer instructions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround detection\u003c\/li\u003e\n\u003cli\u003eArc fault protection\u003c\/li\u003e\n\u003cli\u003eIsland protection\u003c\/li\u003e\n\u003cli\u003eInsulation resistor detection\u003c\/li\u003e\n\u003cli\u003eResidual current monitoring unit\u003c\/li\u003e\n\u003cli\u003eOutput over-current protection\u003c\/li\u003e\n\u003cli\u003eBackup output short protection\u003c\/li\u003e\n\u003cli\u003eOutput over-voltage protection\u003c\/li\u003e\n\u003cli\u003eOutput under-voltage protection\u003c\/li\u003e\n\u003cli\u003eRapid shutdown system support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications and Grid Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSafety: UL1741, UL1741 SA \u0026amp; SB all options, UL1699B, CSA C22.2 No.107.1-01\u003c\/li\u003e\n\u003cli\u003eRapid shutdown: RSD listed by supplier with NEC 690.5, 690.11, and 690.12 references\u003c\/li\u003e\n\u003cli\u003eEMC: FCC Part 15 Class B\u003c\/li\u003e\n\u003cli\u003eGrid connection standards: IEEE 1547, IEEE 2030.5, HECO Rule 14H, CA Rule 21 Phase I, II, III, CEC, CSIP, SRD2.0, SGIP, OGPe, NOM, California Prop 65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12kW hybrid inverter power\u003c\/strong\u003e for solar, battery, grid, backup, and generator-supported systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplit phase output support\u003c\/strong\u003e for 110\/220V, 120\/240V split phase, 208V, and 230V applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18kW max DC input power\u003c\/strong\u003e with 4 MPPT trackers for flexible solar array design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 independent MPPTs\u003c\/strong\u003e with up to 16A max input current per MPPT.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48V battery input\u003c\/strong\u003e compatible with lithium and lead-acid batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250A max charging current\u003c\/strong\u003e and \u003cstrong\u003e260A max discharging current\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200A max grid passthrough current\u003c\/strong\u003e for supported backup and grid-connected applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup output support\u003c\/strong\u003e with 12kVA nominal apparent power and up to 13.2kVA with PV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple working modes\u003c\/strong\u003e, including self-use, peak shift, and battery priority.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator function and AC coupling support\u003c\/strong\u003e for expanded system flexibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel connection support\u003c\/strong\u003e to increase system power when designed correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolarman App monitoring\u003c\/strong\u003e for remote system data, power generation, consumption, battery, grid, load, and alarm information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS485 and CAN communication\u003c\/strong\u003e, with optional Wi-Fi and 4G connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated PV switch\u003c\/strong\u003e and LCD display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 \/ NEMA 3R enclosure\u003c\/strong\u003e for durable installation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL, CSA, IEEE, FCC, HECO, and California Rule 21 related certifications and standards\u003c\/strong\u003e listed by the supplier.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN3H-X12US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInverter Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax DC Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Nominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Grid Passthrough Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 4,000m, derating above 2,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Emission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e495 x 900 x 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConduit and Installation Data\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBackup conduit: 2 inches\u003c\/li\u003e\n\u003cli\u003eGrid conduit: 2 inches\u003c\/li\u003e\n\u003cli\u003eAC solar conduit: 2 inches\u003c\/li\u003e\n\u003cli\u003ePV input conduit: 2 inches\u003c\/li\u003e\n\u003cli\u003eBattery input conduit: 2 inches\u003c\/li\u003e\n\u003cli\u003ePV switch: Integrated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupported System Functions\u003c\/h2\u003e\n\u003cp\u003eThe Amensolar N3H-X12US can convert DC power from solar panels into AC power for home or commercial use. It can also integrate with battery storage systems to store excess energy for later use, such as nighttime operation or cloudy-day backup.\u003c\/p\u003e\n\u003cp\u003eThe inverter also supports smart grid connection and bi-directional power flow. Exporting excess power to the grid depends on local utility approval, net metering availability, and applicable regulations.\u003c\/p\u003e\n\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSplit phase hybrid inverter\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eHanging rack\u003c\/li\u003e\n\u003cli\u003eWi-Fi module\u003c\/li\u003e\n\u003cli\u003eParallel cable\u003c\/li\u003e\n\u003cli\u003eExpansion screws and pan-head screws\u003c\/li\u003e\n\u003cli\u003eSplit core CT\u003c\/li\u003e\n\u003cli\u003eRapid shutdown system transmitter, optional according to supplier listing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential solar plus battery backup systems\u003c\/li\u003e\n\u003cli\u003e48V battery storage installations\u003c\/li\u003e\n\u003cli\u003eGrid-tied solar systems with backup capability\u003c\/li\u003e\n\u003cli\u003eGenerator-supported hybrid energy systems\u003c\/li\u003e\n\u003cli\u003eSelf-use, battery priority, and peak shifting energy setups\u003c\/li\u003e\n\u003cli\u003eSolar installations requiring 120\/240V split phase support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eImportant Installation Note\u003c\/h2\u003e\n\u003cp\u003eThis inverter should be installed by a qualified professional according to the manufacturer’s instructions, local electrical codes, utility requirements, and all applicable safety standards. Grid export, generator integration, battery compatibility, and parallel system design should be confirmed before installation.\u003c\/p\u003e\n\u003chr data-start=\"1215\" data-end=\"1218\"\u003e\n\u003ch3 data-start=\"1220\" data-end=\"1369\"\u003e\u003cstrong data-start=\"1220\" data-end=\"1245\"\u003eOfficial Datasheet\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cbr data-start=\"1245\" data-end=\"1248\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eDownload the complete technical details here:\u003c\/span\u003e\u003cbr data-start=\"1287\" data-end=\"1290\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003ca href=\"https:\/\/www.amensolaress.com\/uploadfile\/202507\/AMENSOLARN3H-X1216USDATASHEET20250605_1.pdf\" rel=\"noopener noreferrer\" data-start=\"0\" data-end=\"132\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eAmensolar N3H‑X12US Hybrid Inverter Datasheet (PDF)\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch2 data-start=\"1220\" data-end=\"1369\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eManual\u003cbr\u003e\u003ca href=\"https:\/\/www.amensolaress.com\/uploadfile\/202512\/N3H-X1216USUserManual-20250606_2.pdf\" rel=\"noopener noreferrer\" data-start=\"0\" data-end=\"132\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eAmensolar N3H‑X12US Hybrid Inverter Datasheet Manual\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e","brand":"Amensolar","offers":[{"title":"Default Title","offer_id":55167422136611,"sku":null,"price":3300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/2537\/9875\/files\/N3H-X12US_200A.jpg?v=1780151705","url":"https:\/\/www.offgridlux.com\/products\/amensolar-hybrid-inverter-12000w-n3h-x12us-200a","provider":"OffGrid Lux","version":"1.0","type":"link"}